Knowledgebase: Enterprise
"Error sending message. Winsock error code 10038" when Attempting to Run Server Based Consolidation
Posted by Priya Doyle on 16 February 2011 11:32 AM

"Error sending message. Winsock error code 10038" when Attempting to Run Server Based Consolidation

 Modified 12-JAN-2011     Type PROBLEM

Applies to:

Hyperion Enterprise - Version: 4.3.2.0.00 and later   [Release: 4.3 and later ]

Microsoft Windows (32-bit)

Symptoms

When attempting to run server based consolidation on an enterprise application the following error occurs: "Error sending message. Winsock error code 10038" 

Cause

The enterprise application is not listed in the hypent.ini on the enterprise application server

Solution

To add the application to the hypent.ini on the application server launch enterprise from the application server and refer to document 580746.1
(0 vote(s))
Helpful
Not helpful

Comments (0)